Aereco ventilators
Aereko’s hit products, which is also offered by Oknovid, are a higro-operated ventilators EMM, EAH and AMI. At present higro-operated elements are installed in public-use buildings, namely, schools, hospitals and offices, however, they are becoming more and more popular in private premises, too.
Higro-operated, double-stream ventilator – EMM
Use: kitchen, bedrooms, dining room, guestroom, and more.
- Higro-operated, double-stream ventilator enables air supply from the outside into the room
- Installed in the upper window part, applicable for new and already installed windows
- The stream depends on the relative humidity level in the room
- Constantly optimizes the air stream for each room, depending on ventilation needs
- Provides proper ventilation without heat loss
- Supplied with stream minimizing blocking system
- Does not demand electrical supply
Basic technical specification:
- work spectrum of 30 do 70% relative humidity inside,
- air stream from 5 to 35 m3/h,
- acoustic absorption 33 dB(A) (with a standard hood)
Higro-operated, acoustic ventilator – EHA
Use: kitchen, bedrooms, dining room, guestroom, and more.
- Higro-operated, double-stream ventilator enables air supply from the outside into the room
- It is characterized by very high noise reduction levels. Installed in the upper window part, applicable for new and already installed windows
- The stream depends on the relative humidity level in the room
- Constantly optimizes the air stream for each room, depending on ventilation needs
- Provides proper ventilation without heat loss
- Supplied with stream minimizing blocking system
- Does not demand electrical supply
- Easy to maintain
- Esthetic
Basic technical specification:
- work spectrum of 30 do 70% relative humidity inside,
- air stream from 5 to 35 m3/h , (optionally: 20-50 m3/h)
- acoustic absorption from 37 up to 42dB (A) (depending on a model)
Pressure window ventilator - AMI
- Pressure ventilator enables air supply from the outside into the room
- Installed in the upper window part, applicable for new and already installed windows.
- The stream depends on the relative humidity level in the room
- Constantly optimizes the air stream for each room, depending on ventilation needs
- Provides proper ventilation without heat loss
- Might be supplied with stream minimizing blocking system
- Does not demand electrical supply
- Easy to maintain
- Esthetic
Basic technical specification:
- air stream from 22 to 30 m3/h,
- acoustic absorption from 37 and 39 dB(A)